The products > Measuring devices > ALPTEC power factor controller > Technical characteristics

> ALPTEC Power factor controller
> Technical characteristics

ALPTEC Power factor controller

TECHNICAL CHARACTERISTICS

Auxiliary supply ALPTEC 3 ALPTEC 5 ALPTEC 7 ALPTEC 12
Rated voltage Ue

380 to 415 Vac (other value on request)

Operating limit

-15% to +10% Ue

Rated frequency

50 or 60Hz +- 1% (self configurable)

Maximum consumption

6.2Va

5Va

Maximum power dissipated

2.7W

3W

Maximum power dissipated by output contact

0.5W with 5A

Immunity time for micro breakings

30 ms

No-voltage release

8 ms


Current input

Rated current le 5A (1A on request)
Operating limit 0.125 to 6A
Constant overload +20%
Type of measurement True RMS
Short time withstand current 10le for 1 s
Dynamic limit 20le for 10 ms
Input power 0.65 W

Control range  
Power factor setting 0.80 ind to 0.80 cap
Reconnection time of the same step 5 to 240 s
Sensitivity 5 to 600 s / step

Output relay ALPTEC 3 ALPTEC 5 ALPTEC 7 ALPTEC 12
Number of outputs 3 5 7 12
Type of outputs 3 3+2 C/O/F 5+2 C/O/F 10+2 C/O/F
Maximum current at contact common 12A
Rated capacity lth 5A
Rated operational voltage 250VAC
Maximum switching voltage 440VAC
Designation according to IEC/EN 60947 5-1 AC-DC C250, B/400
Electrical life at 0.33A 250VAC and AC11 load conditions 5x106 ops
Electrical life et 2A 400VAC and AC11 load conditions 2x106 ops

Operating ambient conditions  
Operating temperature -20°C to +60°C
Storage temperature -30°C to +80°C
Relative humidity < 90%

Connections  
Type of terminal Removale / Plug-in
Cable cross section (min-max) 0.2-2.5 mm2 (24-12AWG)
Tightening torque 0.8Nm (7lbin)

Enclosure ALPTEC 3 ALPTEC 5 ALPTEC 7 ALPTEC 12
Version Flush mount
Material Thermoplastic
NORYL SE1 GNF2
Thermoplastic
LEXAN 3412R
Dimension W x H x D 96 x 96 x 65 mm 144 x 144 x 62 mm
Panel cut out dimension 91 x 91 mm 138.5 x 138.5 mm
Protection degree IP 54 IP 41
(IP 54 with protection cover)
Weight 420 g 440 g 460 g 770 g

Reference standards
IEC/EN 61010-1, IEC/EN 61000-6-2, ENV 50204 ; CISPR 11 / EN 55011 ; 61000-3-3 ; IEC / EN60068-2-6 ; UL508 ; CSA C22.2 N° 14-95

Certification
cULus pending

   

Wiring diagram :

IMPORTANT!
a. For three-phase connection, the voltage input must be connected phase to phase; the current transformer must be connected on the remaining phase.
b. The polarity of the current/voltage input is indifferent.

WARNING!
Disconnect the line and the supply wshen operating on terminals.

    