The products > Measuring devices > Alptec digital multimeters > Technical characteristics

Alptec digital multimeters

Technical characteristics

MEASUREMENTS MADE ALPTEC 50 ALPTEC 60 ALPTEC 200
Phase and phase to phase voltage:  . . .

* instantaneous

. . .

* mean

. .

* minimum

. . .

* maximum

. . .
Current per phase: . . .

* instantaneous

. . .

* mean

  . .

* minimum

. . .

* maximum

. . .

* averaged maximum

. .
Frequency . . .
Power factor . . .
Cos φ   . .
Active power:  . . .

* instantaneous

. . .

* per phase

. . .

* total and bi-directional

  . .

* mean

. .

* minimum

. . .

* maximum

. . .

* averaged maximum

  . .
Reactive power:  . . .

* instantaneous

. . .

* per phase

. . .

* total and bi-directional

  . .

* mean

. .

* minimum

. . .

* maximum

. . .
Apparent power:  . . .

* instantaneous

. .

.

* per phase

. . .

* total and bi-directional

. .

* mean

  . .

* minimum

. . .

* maximum

. . .
Active energy:  . .

* total and bi-directional

  . .
Reactive energy:  . .

* total and bi-directional

  . .
Harmonics (%) --> 21st order: . .

* voltage

  . .

* current

. .

* total distortion

  . .
COMMUNICATION     .
RS 485 (MODBUS - RTU protocol) .
1 programmable electromechanical relay     .
1 programmable solid state relay .

 

ELECTRICAL CHARACTERISTICS  
Voltage input:  

* direct without voltage transformer

10 to 830 VAC

* with voltage transformer

Primary 69000 V max.

* consumption per phase

0.7 VA
Current input:   

* direct without current transformer

0.02 to 5 A (+20% permitted)

* with current transformer

Primary 10000 A max.

* consumption per phase

0.3 VA
Frequency input 45 to 65 Hz
Measurements (power, energy, etc.) In all 4 quadrants (except Alptec 50: 2 quadrants)
Types of measurement True RMS
Connection mode Single, two or three phase, with or without neutral
Measurement precision:  

* voltage, current, power

+/-0.5%

* energy

+/-1%
Display refresh time Every 300 milliseconds (except Alptec 50: 1s)
Characteristics of electromechanical output relay:  

* current / contact voltage

5 A/250 VAC
Characteristics of solid state output relay:  

* type

Bi-directional

* current: voltage

55 mA/60 VAC and DC
Characteristics of RS 485 serial link

* type

Isolated

* Programmable band rate

2400 to 19200 bps
Display immunity against power line disturbance 20 milliseconds
Backup of parameters and acquisitions permanent backup
Auxiliary power supply 208 to 240VAC/50-60Hz/10VA
 
ADJUSTABLE CHARACTERISTICS  
Integration time for energy values and averaged maximum 1 to 60 minutes
Current transformer ratio 1 to 2000
Voltage transformer ratio 1 to 1000
Network type  Single, two or three phase
 
USAGE CHARACTERISTICS  
Operating temperature -20 to +60° C
Storage temperature -30 to +80° C
Humidity <90%
Protection index IP 41
 
MECHANICAL CHARACTERISTICS  
Dimensions (L x W x D)

* flush fitting

96 x 96 x 91 mm

* DIN rail

105 x 90 x 60 mm
Weight 0.4 kg
 
STANDARDS  
CEI / EN 50081-1 and 50082-2
CEI / EN 61040-1
CEI / EN 60068-2-6-27
CEI / EN 61000-4-11
 